function dq=delq(Ts,Ta,rh) % DELQ: computes air-sea specific humidity difference. % dq=DELQ(Ts,Ta,rh) computes the specific humidity (kg/kg) difference % between the air (as determined by relative humidty rh and air % temperature Ta measurements) and the sea surface (where q is % assumed to be at 98% satuation at the sea surface temperature Ts). % DELQ uses QSAT based on Tetens' formula for saturation vapor % pressure from Buck (1981), J. App. Meteor., 1527-1532. The % dependence of QSAT on pressure is small (<0.5%) and has been % removed using a mean pressure of 1020 mb. % % INPUT: Ts - sea surface temperature [C] % Ta - air temperature [C] % rh - relative humidity [%] % % OUTPUT: dq - air-sea specific humidity difference [kg/kg] %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% % 3/8/97: version 1.0 % 4/10/98: version 1.1 % 8/5/99: version 2.0 %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% dq=0.01.*rh.*qsat(Ta) - 0.98.*qsat(Ts);